Scherzo SM-C18 multi-mode ODS HPLC Column
Scherzo SM-C18 Anion Exchange + Cation Exchange + Normal Phase + Reversed Phase HPLC Column
Imtakt Part Number: SM003
World’s first ODS column with Anion and Cation Exchange. Weak ionic ligands adequately bonded to this material optimized for the separation of basic/acidic compounds at neutral pH.
Download the Scherzo C18 Family Brochure
Column Specifications:
ID: | 4.6 mm |
Length: | 75 mm |
Particle Size (Microns): | 3 μm |
Pore size: | 13 nm |
Pressure: | Up to 250 bar / 3500 psi |
Mode: | multi-mode ODS (Anion Exchange + Cation Exchange + Normal Phase + Reversed Phase) |
- Simultaneous analysis for both cationic and anionic compounds
- ODS + IEX or Reversed Phase + Normal Phase
- For polar compounds
- LC-MS compatible without using ion-pair reagent
Purified Porous Silica / Particle Size 3um / Pore Size 13nm / ODS + Anion Exchange + Cation Exchange Ligands
Imtakt has developed a revolutionary multi-mode ODS column.
Many biomaterials / metabolites are ionic and cannot be retained on conventional ODS columns. Recent solutions for this issue have the following limitations:
- Ion-pairing RP chromatography is not compatible with LC-MS
- Aqueous NP (HILIC) fails to separate polar & non-polar compounds
Scherzo SM-C18 can solve many of these problems. SM-C18 contains ODS+cation+anion ligands and can be used to separate highly polar compounds. Unlike other mixed-mode RP columns, Scherzo SM-C18 contains ODS ligands, and shows similar behavior to conventional ODS columns for non ionic compounds. In addition, the IEX ligands on SM-C18 are highly polar and provide normal phase mode. This allows for both RP + NP separation mode. This next generation (multi-mode) ODS column expands the separation possibilities for the ODS phase.
Separation mechanism on multi-mode ODS (RP + Anion Ex.+ Cation Ex.)
Scherzo SM-C18 is a multi-mode ODS column that provides the following modes of separation:reversed-phase, anion exchange, and cation exchange. These interactions enable the separation of water-soluble vitamins without the use of ion-pairing reagents.
Separation mechanism on multi-mode ODS (RP + Anion Ex.+ Cation Ex.)
Conventional ODS columns can struggle to retain polar ionic compounds. But Scherzo SM-C18
will be useful in separating both anionic and cationic compounds. Strong ionic compounds, such as quaternary amines or sulfonic acids, can be difficult to retain / separate on conventional ODS. Mixed-mode RP columns have a single ionic ligand (anion or cation) and struggle to retain both acidic and basic compounds. Separation of both acids and bases require two different methods with two different mixed-mode RP columns. In contrast, the multi-mode ODS column, Scherzo SM-C18, consists of both anionic and cationic ligands. Separation of both cations and anions is possible using one column and one method.
Recommendations for Scherzo SM-C18
Scherzo SM-C18 consists of ODS, anion, and cation ligands. The stationary phase interacts with ionic
solutes which can sometimes lead to fluctuating retention and separation (due to electric charge
between eluent and stationary phase). The following recommendations should be considered for
reproducibility and ruggedness.
Confirm the reproducibility by repeat-injections
Variable retention / separation can be observed during repeat injections due to variable dissociation of ligands on the stationary phase. To confirm optimized condition, several injections are recommended. If retention is not reproducible, it is recommended to either increase ionic strength in eluent or change to gradient elution.
Salt concentration in sample solution
Acidic and basic compounds in sample solution may interact with each other forming complexes which can have a detrimental effect on peak shape due to undesirable dispersion within the column. It is therefore recommended to add salt, acid, or alkali to the sample solution in order to avoid this problem.
Do not use pH meter. Buffer in eluent should be prepared by mixing of acid and base solutions
Buffers prepared with pH meters (e.g. titrate to desired pH) are not reproducible. Precision for [salt] and pH is crucial for buffers used with HPLC. It is strongly recommended to prepare buffers by measuring appropriate volumes of (equal concentration) acid and base solutions. Buffer concentration should be optimized for each method.
Range of Scherzo SM-C18 Columns
Particle: 3um Silica, Pore Size: 30nm, Ligand: ODS + Anion Exchange + Cation Exchange
Product Number | |||||||
Length (mm) | Analytical | Semi-prep | |||||
1 mm I.D. | 1.5 mm I.D. | 2 mm I.D. | 3 mm I.D. | 4.6 mm I.D | 6 mm I.D. | 10 mm I.D | |
10 | - | - | SM020 | SM030 | SM000 | - | - |
20 | - | - | SM029 | SM039 | SM009 | - | - |
30 | SM011 | SM071 | SM021 | SM031 | SM001 | SM061 | SM0P1 |
50 | SM012 | SM072 | SM022 | SM032 | SM002 | SM062 | SM0P2 |
75 | SM013 | SM073 | SM023 | SM033 | SM003 | SM063 | SM0P3 |
100 | SM014 | SM074 | SM024 | SM034 | SM004 | SM064 | SM0P4 |
150 | SM015 | SM075 | SM025 | SM035 | SM005 | SM065 | SM0P5 |
250 | SM016 | SM076 | SM026 | SM036 | SM006 | SM066 | SM0P6 |
500 | - | - | - | - | SM007 | - | - |
Guard Holder (Column coupler enclosed)
Separation column ID | Product Code |
for 1 - 6 mm I.D. | GCH01S |
for 10 mm I.D. | GCH02M |
Guard Cartridge SM-C18
Separation column ID | Product Code | Note |
for 1-1.5 mm I.D. | GCSM0C | 5 x 1 mm, 3 pcs |
for 2 - 6 mm I.D. | GCSM0S | 5 x 2 mm, 3 pcs |
for 10 mm I.D. | GCSM0M | 10 x 8 mm, 2 pcs |
SM-C18 Metal Free Columns
Column Length (mm) | 2.0 mm I.D. Analytical Columns Available |
30 | SM021F |
50 | SM022F |
75 | SM023F |
100 | SM024F |
150 | SM025F |
250 | SM026F |
Additional Imtakt Columns Available
- Model: SM003
- Manufactured by: Imtakt