Unison UK-Amino 3μm Column, Durable against water elusion
Unison UK-Amino (Aminopropyl) 3μm, 50mm x 10mm, 130Å Semi-Preparative HPLC Column, Pressure Limits of up to : 20MPa, 250 bar, 3,500 psi
Imtakt Product Number: UKAP2
Column Specifications:
| Base Material: | Silica | 
| Quantity: | 1 piece | 
| Chemistry: | NH2 (Amino) | 
| Manufacturer Chemistry Name: | UK-Amino | 
| Endcapping: | - | 
| Matrix: | Silica | 
| Brand: | Imtakt Unison | 
| Internal Diameter: | 10 mm | 
| Length: | 50 mm | 
| Particle Morphology: | spherical, porous | 
| Particle Size: | 3 μm | 
| Pressure Stability: | up to 250 bar | 
| Pore Size: | 130 Å | 
| Technology: | HPLC | 
| USP Class: | L8 | 
High quality long-life Amino column for carbohydrate or Hilic separations.
The Unison Family of columns provide a wide range of high quality reverse phase and normal phase columns. The quality of our material provides high efficiency with low backpressure and 100% aqueous stability. Peak shape is also improved with the use of our polymeric end-capping technology. The Unison series of columns are available with C18, C8, Phenyl, Amino and Silica stationary phases to meet a wide range of chromatographic needs.
- Pure spherical porous silica 3µm particle Aminopropyl phase
 - High efficiency 3µ columns with mono-dispersed packing for low backpressure
 - Normal phase aminopropyl material ideal for analysis of sugars and carbohydrates
 - World class reproducibility
 - HT and UP hardware able to operate in pressures up to 1000 bar
 - High efficiency and available short column dimensions are ideal for high throughput applications
 - Aqueous to non-aqueous Normal Phase separation
 - LC-MS applicable
 - Unique ligand binding strategy provides dramatically longer lifetimes and lower bleed compared to other amino columns
 
Aqueous durable silica-based aminopropyl columns have been used for a long time as a normal phase column for carbohydrate separation. However, these aminopropyl columns have a fatal flaw: "column bleeding" or the rapid deterioration in retention as a result of ligand desorption under aqueous elution.
Unison UK-Amino offers a different approach from conventional columns: high durability against aqueous eluent. As the above chromatogram demonstrates, conventional columns experience a significant decline in retention when an aqueous mobile phase elutes through the column. UK-Amino, on the other hand, does not show any change in separation or retention. This is a significant development in the history of aminopropyl columns.
UK-Amino's design not only provides analytical power, but the 3um particle high-resolution column has other benefits, including the minimization of LC-MS and LC-ELSD noise levels. UK-Amino can be applied to aqueous normal phase conditions, and separation optimization is possible while comparing to ODS columns using reversed-phase mode. One can expect significant results from this normal phase column of UK-Amino.
Range of Unison UK-Amino 3µm Columns, Product Numbers:
| Column Length (mm) | Analytical | Semi-prep | |||||
| 1.0 mm I.D. | 1.5 mm I.D. | 2.0 mm I.D. | 3.0 mm I.D. | 4.6 mm I.D. | 6.0 mm I.D. | 10.0 mm I.D. | |
| 3 µm Columns, Pressure Limits of up to : 20MPa, 250 bar, 3,500 psi | |||||||
| 10 | UKA20 | UKA30 | UKA00 | ||||
| 20 | UKA29 | UKA39 | UKA09 | ||||
| 30 | UKA11 | UKA71 | UKA21 | UKA31 | UKA01 | UKA61 | UKAP1 | 
| 50 | UKA12 | UKA72 | UKA22 | UKA32 | UKA02 | UKA62 | UKAP2 | 
| 75 | UKA13 | UKA73 | UKA23 | UKA33 | UKA03 | UKA63 | UKAP3 | 
| 100 | UKA14 | UKA74 | UKA24 | UKA34 | UKA04 | UKA64 | UKAP4 | 
| 150 | UKA15 | UKA75 | UKA25 | UKA35 | UKA05 | UKA65 | UKAP5 | 
| 250 | UKA16 | UKA76 | UKA26 | UKA36 | UKA06 | UKA66 | UKAP6 | 
| 3 µm Columns, Pressure Limits of up to : 50MPa, 500 bar, 7,500 psi | |||||||
| 10 | UKA20T | UKA30T | UKA00T | ||||
| 20 | UKA29T | UKA39T | UKA09T | ||||
| 30 | UKA11T | UKA71T | UKA21T | UKA39T | UKA01T | ||
| 50 | UKA12T | UKA72T | UKA22T | UKA32T | UKA02T | ||
| 75 | UKA13T | UKA73T | UKA23T | UKA33T | UKA03T | ||
| 100 | UKA14T | UKA74T | UKA24T | UKA34T | UKA04T | ||
| 150 | UKA15T | UKA75T | UKA25T | UKA35T | UKA05T | ||
| 250 | UKA16T | UKA76T | UKA26T | UKA36T | UKA06T | ||
| 3 µm Columns, Pressure Limits of up to : 100MPa, 1000 bar, 15,000 psi | |||||||
| 30 | UKA21U | ||||||
| 50 | UKA22U | ||||||
| 75 | UKA23U | ||||||
| 100 | UKA24U | ||||||
| 150 | UKA25U | ||||||
| 250 | UKA26U | ||||||
| 3 µm Metal-Free Columns Pressure Limits of up to : 50MPa, 500 bar, 7,500 psi | |||||||
| 30 | UKA21F | ||||||
| 50 | UKA22F | ||||||
| 75 | UKA23F | ||||||
| 100 | UKA24F | ||||||
| 150 | UKA25F | ||||||
| 250 | UKA26F | ||||||
Column Guard System for Unison UK-Amino:
| Product Code | Product Name | Product Description | 
| GCUKAC | Guard Cartridge UK-Amino | 3um,Aminopropyl (5x1mm), 3pcs | 
| GCUKAM | Guard Cartridge UK-Amino | 3um,Aminopropyl (10x8mm), 2pcs | 
| GCUKAS | Guard Cartridge UK-Amino | 3um,Aminopropyl (5x2mm), 3pcs | 
| GCH01S | Guard Holder | Guard Holder for 1-6mmI.D. separation columns | 
| GCH02M | Guard Holder | Guard Holder for 10-20mmI.D. separation columns | 
| GCH11S | Guard Holder | Guard Holder for 4.6mm column, enclosed an U-Shape column coupler | 
| GCH12M | Guard Holder | Guard Holder for 10-20mm column, enclosed an U-Shape column coupler | 
All stationary phases can also be made in the following internal diameters, please contact our Sales Team with your specificatons: Nano: 0.02mm, 0075mm | Capillary: 0.1mm, 0.3mm, 0.5mm | Semi-Prep: 20mm, 28mm.
This Column is also Available in 5μm!
Additional Imtakt Columns Available
- Model: UKAP2
 - Manufactured by: Imtakt
 

					
											