Hitachi Chromaster 5260 HPLC Autosampler
Chromaster 5260 HPLC Autosampler: Withstand pressure 60 MPa, Loop injection method
Please contact our Sales Team with your laboratory requirements and specifications including PC equipment and Software. Uvison service contracts are also available - please see our Engineering section for further information - https://uvison.com/engineering |
This Autosampler is available in the following configurations - please specify when ordering:
- Chromaster HPLC 5260 autosampler with 175 µl syringe. 600 bar max. operating pressure
- Chromaster HPLC 5260 autosampler with thermostat and 175 µl syringe. 600 bar max. operating pressure
- Availble with and without rack temperature control
Autosampler with thermostat (5260 Autosampler) - Capable of heating up to 45 °C
The Autosampler with thermostat is capable of controlling the temperature (in a vial) from 21 °C below ambient temperature to ambient temperature + 25 °C*7. This level of vial temperature control broadens the application range and maintains sample stability by preventing crystallization of sample components in the vial. (Autosamplers are available with and without a thermostat.)
*7 Temperature setting range: 1 to 45 °C
Dedicated degassing unit for autosampler (5260 Autosampler) - Space-saving built-in degassing unit
The Chromaster autosampler incorporates a dedicated degassing unit*8. When the user wants to operate the Chromaster autosampler without Chromaster pump, this degassing unit has great utility. Moreover, because it can be a built-in unit, the degassing unit does not take up extra bench space.
*8 Optional
Loop injection autosampler for lower carry-over
5260 autosampler is equipped with a wash pump which provides highly efficient washing for the needle outer wall in order to achieve lower carry-over. As a result, the carry-over is as low as that from the direct injection system. In addition, the standard installation includes a two-solvent washing function for the needle inner wall to ensure low carry-over even for the analysis of the most persistent components.
FEATURES
- Integrated wash pump
- Holds 200 1.5ml vials
5260 Main optional accessories - please specify when ordering
- Sample rack (4 ml × 72)
- Thermostat rack (4 ml × 72)
- Sample rack (1 ml × 195)
- Thermostat rack (1 ml × 195)
- Micro plate rack (2 pcs)
- Thermostat micro plate rack (2 pcs)
- Syringe kit (70 μl, 700 μl)
- Sample loop kit (5 μl, 10 μl, 20 μl)
- 2-channel Degassing unit (250 μl / ch)
- UI Pad for 5260
- AC adapter (150 W)
- Hexane kit for 5210/5260
- THF kit for 5210/5260 - Withstand pressure 40 MPa
- Interface control board (IFC board) (for installing a 5260 autosampler)
SPECIFICATIONS:
Item | 5260 | |
---|---|---|
Sample injection method | Cut injection method; All volume injection method; Full loop injection method | |
Withstand pressure | 60 MPa | |
Washing function | Equipped with built-in washing pump Two-solvent washing function |
|
Sample rack temperature control | 1 to 45 °C | |
(Temperature setting range) | Capable of cooling and heating | |
Maximum number of samples | 120 (1,5 ml); 72 (4 ml) (option); 195 (1 ml) (option); 192 (96-holes microplate x 2) (option); 768 (384-holes microplate x 2) (option) | |
Reproducibility of injection volume | ≤0,2% RSD (in 10 µl injection, Cut injection method); ≤1,0% RSD (in 1 µl injection, All volume injection method; ≤0,2% RSD (in 5 µl injection, Full loop injection method) | |
Carryover | ≤0,003% (Cut injection method) | |
Linearity of injection volume | Correlation coefficient: ≥0,999 (Cut injection method) | |
Injection volume accuracy | ±2% | |
Minimum injection operating time | Approx. 28 s (stand-alone) | |
Thermostat (option) | 1 to 45 °C (in increments of 1 °C) | |
Optional accessories | UI-PAD (Keyboard) | |
Sample capacity | Standard | 120 × 1.5 mL |
Optional | 72 × 4 mL |
Also Available:
- Model: CM 5260 / CM5260
- Manufactured by: Merck Hitachi