Hitachi Chromaster 5280 HPLC Autosampler
Chromaster 5280 HPLC Autosampler: Withstand pressure 60 MPa, Loop injection method
| 
			 Please contact our Sales Team with your laboratory requirements and specifications including PC equipment and Software. Uvison service contracts are also available - please see our Engineering section for further information - https://uvison.com/engineering  | 
		
This Autosampler is available in the following configurations - please specify when ordering:
- Chromaster HPLC 5280 autosampler with peltier cooling unit and 100 µl syringe. 600 bar max. operating pressure
 - Chromaster HPLC 5280 autosampler with 100 µl syringe. 600 bar max. operating pressure
 - Availble with and without rack temperature control
 
Loop injection autosampler for lower carry-over
5260 autosampler is equipped with a wash pump which provides highly efficient washing for the needle outer wall in order to achieve lower carry-over. As a result, the carry-over is as low as that from the direct injection system. In addition, the standard installation includes a two-solvent washing function for the needle inner wall to ensure low carry-over even for the analysis of the most persistent components.
Additional settings to reduce carry-over
- Needle outer wall washing prior to sample drawing
 - Two-solvent washing is available for the needle inner wall/inside the injection valve
 
FEATURES
- Integrated wash pump
 - Holds 200 1.5ml vials
 
5280 Main optional accessories - please specify when ordering
- Sample rack (4 ml × 128)
 - Thermo unit rack (4 ml × 128)
 - Micro plate rack (3 pcs)
 - Thermo unit micro plate rack (3 pcs)
 - Syringe kit (500 μl, 1 ml)
 - UI Pad for 5280
 - AC adapter (150 W)
 
SPECIFICATIONS:
| Item | 5280 | |
|---|---|---|
| Sample injection method | Direct injection method | |
| Withstand pressure | 60 MPa | |
| Washing function | Wash solvent delivery by a syringe | |
| Sample rack temperature control | 1 to 35 °C | |
| (Temperature setting range) | Cooling only | |
| Maximum number of samples | 200 (1,5 ml); 128 (4 ml) (option); 288 (96-holes microplate x 3) (option); 1152 (384-holes microplate x 3) (option) | |
| Reproducibility of injection volume | ≤0,3% RSD (in 10 µl injection) | |
| Syringe capacity | 100 µl (standard); 500 µl (option); 1 ml (option) | |
| Carryover | ≤0,003% | |
| Linearity of injection volume | Correlation coefficient: ≥0,999 (Cut injection method) | |
| Injection volume accuracy | ±2% | |
| Minimum injection operating time | Approx. 28 s (stand-alone) | |
| Thermostat (option) | 1 to 35 °C (in increments of 1 °C) | |
| Optional accessories | UI-PAD (Keyboard) | |
| Sample capacity | Standard | 200 × 1.5 mL | 
| Optional | 128 × 4 mL | |
Also Available:
- Model: CM 5280 / CM5280
 - Manufactured by: Merck Hitachi
 

					
											