Hitachi Chromaster 5410 UV Detector
Chromaster HPLC 5410 UV variable wavelength detector - 190 to 600 nm Wavelength Range - 13 μl Flow Cell Included
Please contact our Sales Team with your laboratory requirements and specifications including PC equipment and Software. Uvison service contracts are also available - please see our Engineering section for further information - https://uvison.com/engineering |
FEATURES
Thermostat flow cell
Thermostat controlled flow cell minimizes the influence of ambient temperature changes. As a result, the baseline of detector is steady and data reliability improved.
Ultraviolet (UV) region wavelength check by means of a built-in Hg lamp
The emission lines of built-in D2 and Hg lamps allow wavelength checks over the ultraviolet to visible range. As there is no physical change with the Hg lamp over time, the accuracy check will result in highly reliable data.
Low noise, low drift, and a high sensitivity detection
A noise level can achieve 0,5 × 10-5 AU*2 (or less) can be achieved, allowing better sensitivity than ever With a low drift of 1,0 × 10-4 AU / hr*3 (or less), these detectors deliver excellent baseline stability. *2, 3 Under a specified condition
Two-wavelength simultaneous measurement function
The two-wavelength detection function*4 permits measurements at short data acquisition intervals of 400 ms*5 and 800 ms per wavelength. The result is chromatograms with sharp peak shapes.
*4 Controlled by CDS only
*5 400 ms is available only if the wavelength interval is 160 nm or less.
OPTIONAL ACCESSORIES
Please specify when ordering
- UI Pad for 5410/5420
- Chromaster HPLC thermo cell. Flow cell control unit for 5410 UV detector and
5420 UV-VIS detector is also required - Chromaster HPLC thermo cell. Flow cell control unit for 5410 UV detector and 5420 UV-VIS detector is also required
- Chromaster HPLC thermostat cell control unit. Necessary for thermo cell for 5410 UV detectors and 5420 UV-VIS detectors
- Chromaster HPLC high pressure semi-micro flow cell, 150 bar, 3,2 μl, 5 mm
- Chromaster HPLC preparative flow cell, path length 0.5mm volume 9.8μL, pressure resistance 1MPa
- Chromaster HPLC 1-channel analogue signal output unit
- Chromaster HPLC AC adapter (150 W)
- Chromaster HPLC semi-micro flow cell kit including capillary set for low dispersion
SPECIFICATIONS
Optical system | Double beam |
Light source | D2 lamp |
Measuring wavelength range | 190 to 600 nm |
Measuring mode | 1-wavelength and dual-2wavelength-mode |
Spectral bandwidth | 6 nm |
Wavelength accuracy | ±1 nm |
Noise | ≤−0,5 × 10−5 AU at 250 nm, under a specified condition |
Drift | ≤−1,0 × 10−4 AU/h at 250 nm, under a specified condition |
2-wavelength measurement | 2 wavelengths in wavelength regions 190 to 350 nm and 351 to 600 nm, respectively (Minimum wavelength interval 5 nm, max. wavelength interval 160 nm with data sampling period set at 400 ms) |
Response | 0,01 sec, 0,02 sec, 0,05 sec, 0,1 sec, 0,5 sec, 1 sec, 2 sec |
Materials of wetted parts | Quartz glass, fluororesin, stainless steel |
Functions of GLP | (a) D2 lamp/Hg lamp lighting time, lighting number of times, and replacement record (b) Key lock (c) D2 lamp energy check and D2 lamp wavelength check (d) Hg lamp wavelength check |
Flow cell | Quartz, SUS, Fluororesin (path length 10 mm, cell capacity 13 μl) |
Thermostatically flow cell | Optional, environmental temperature range: 4 to 30 °C |
Dimensions and weight | 340 (W) × 440 (D) × 140 (H) mm, approx. 14 kg |
Power supply and Power consumption | DC24 V, 2,5 A (maximum)/60 W (power supply from organizer) Please purchase the AC adaptor (150 W) when there is no organizer. |
Withstand pressure of flow cell | 1,0 MPa |
Optional accessories | UI-PAD (Keyboard); Thermo. Cell |
CHROMASTER DETECTORS AVAILABLE
- 5410 UV Detector
- 5420 UV-VIS Detector
- 5430 DAD Detector
- 5440 Fluorescence FL Detector
- 5450 RI Detector
- 5610 MS Detector
- Model: CM 5410 / CM5410
- Manufactured by: Merck Hitachi