Hitachi Chromaster 5430 Diode Array Detector (DAD)
Chromaster HPLC 5430 diode array detector - 190 - 900 nm Wavelength Range - Without Flow Cell, Flow Cell must be ordered separately
Please contact our Sales Team with your laboratory requirements and specifications including PC equipment and Software. Uvison service contracts are also available - please see our Engineering section for further information - https://uvison.com/engineering |
FEATURES
Excellent qualitative analysis performance
With a wide wavelength range of 190 nm to 900 nm, the 1,024-bit diode array in Chromaster
Diode array detector delivers the world’s best resolution.
Achievement of further low noise and low drift
The 5430 diode array detector is comparable to conventional Ultraviolet (UV) detectors for baseline noise to 0,5 × 10-5 AU*1 (or less), and is capable of high-sensitivity detection. The adoption of a variable air-volume fan and the provision of a specially designed cover on the spectrometer minimize of influence of temperature change around the optical system and achieves a further reduction in drift to 0,4 × 10-3 AU/hr*1 (or less) and a reduction in lamp stabilization time by about 30% (In-house comparison).
*1 Under a specified condition
Low noise, low drift, and a high sensitivity detection
A noise level can achieve 0,5 × 10-5 AU*2 (or less) can be achieved, allowing better sensitivity than ever. With a low drift of 1,0 × 10-4 AU / hr*3 (or less), these detectors deliver excellent baseline stability.
*2, 3 Under a specified condition
Two-wavelength simultaneous measurement function
The two-wavelength detection function*4 permits measurements at short data acquisition intervals of 400 ms*5 and 800 ms per wavelength. The result is chromatograms with sharp peak shapes.
*4 Controlled by CDS only
*5 400 ms is available only if the wavelength interval is 160 nm or less.
Thermostat controlled flow cell minimizes the influence of ambient temperature changes. As a result, the baseline of detector is steady and data reliability improved.
Ultraviolet (UV) region wavelength check by means of a built-in Hg lamp
The emission lines of built-in D2 and Hg lamps allow wavelength checks over the ultraviolet to visible range. As there is no physical change with the Hg lamp over time, the accuracy check will result in highly reliable data.
OPTIONAL ACCESSORIES
Please specify when ordering
- 2ch Analog signal output unit for 5430
- AC adapter (150 W)
- Semi-micro flow cell unit for 5430
- HP SM flow cell unit for 5430
- Preparative flow cell unit for 5430
- Thermo cell for 5430
- Thermo cell control unit for 5430
SPECIFICATIONS
5430 Diode Array Detector | |
Detection type | 1,024 bit PDA |
Light source | D2 lamp, W lamp, Hg lamp for checking wavelength |
Wavelength range | 190 to 900 nm |
Wavelength accuracy | ±1 nm |
Noise | ≤−0,5 × 10−5 AU at 250 nm, 600 nm, under a specified condition |
Drift | ≤−0,4 × 10−3 AU/h at 250 nm, 600 nm, under a specified condition |
Response | 0,01 sec, 0,02 sec, 0,05 sec, 0,1 sec, 0,5 sec, 1 sec, 2 sec |
Slit type | 1 nm/4 nm (variable) |
Materials of wetted parts | Quartz glass, fluororesin, stainless steel |
Functions of GLP | (a) D2 lamp/W lamp/Hg lamp lighting time, lighting number of times, and replacement record (b) D2 lamp energy check (c) W lamp energy check (d) Hg lamp wavelength check (e) D2 lamp wavelength check |
Flow cell | 13 μl (optical path length 10 mm) |
Thermostat flow cell | Optional, environmental temperature range: 15 to 30 °C |
Dimensions and weight | 340 (W) × 440 (D) × 140 (H) mm, approx. 14 kg |
Power supply and Power consumption | DC24 V, 3.5 A (maximum) /84 W (power supply from organizer) Please purchase the AC adaptor (150 W) when there is no organizer |
CHROMASTER DETECTORS AVAILABLE
- Model: CM 5430 DAD / CM5430
- Manufactured by: Merck Hitachi