Welcome, Sign In First time visitor? Create a New Account
Your cart is empty

Hitachi Chromaster 5430 Diode Array Detector

Price:
Live chat below or contact us for latest price.


Download Data Sheet

Hitachi Chromaster 5430 Diode Array Detector (DAD)

Chromaster HPLC 5430 diode array detector - 190 - 900 nm Wavelength Range - Without Flow Cell, Flow Cell must be ordered separately

Please contact our Sales Team with your laboratory requirements and specifications including PC equipment and Software.

Uvison service contracts are also available - please see our Engineering section for further information - https://uvison.com/engineering 

FEATURES

Excellent qualitative analysis performance
With a wide wavelength range of 190 nm to 900 nm, the 1,024-bit diode array in Chromaster
Diode array detector delivers the world’s best resolution.

Achievement of further low noise and low drift
The 5430 diode array detector is comparable to conventional Ultraviolet (UV) detectors for baseline noise to 0,5 × 10-5 AU*1 (or less), and is capable of high-sensitivity detection. The adoption of a variable air-volume fan and the provision of a specially designed cover on the spectrometer minimize of influence of temperature change around the optical system and achieves a further reduction in drift to 0,4 × 10-3 AU/hr*1 (or less) and a reduction in lamp stabilization time by about 30% (In-house comparison).
*1 Under a specified condition

Low noise, low drift, and a high sensitivity detection
A noise level can achieve 0,5 × 10-5 AU*2 (or less) can be achieved, allowing better sensitivity than ever. With a low drift of 1,0 × 10-4 AU / hr*3 (or less), these detectors deliver excellent baseline stability.
*2, 3 Under a specified condition

Two-wavelength simultaneous measurement function
The two-wavelength detection function*4 permits measurements at short data acquisition intervals of 400 ms*5 and 800 ms per wavelength. The result is chromatograms with sharp peak shapes.
*4 Controlled by CDS only
*5 400 ms is available only if the wavelength interval is 160 nm or less.

Thermostat controlled flow cell minimizes the influence of ambient temperature changes. As a result, the baseline of detector is steady and data reliability improved.

Ultraviolet (UV) region wavelength check by means of a built-in Hg lamp
The emission lines of built-in D2 and Hg lamps allow wavelength checks over the ultraviolet to visible range. As there is no physical change with the Hg lamp over time, the accuracy check will result in highly reliable data.

OPTIONAL ACCESSORIES

Please specify when ordering

  1. 2ch Analog signal output unit for 5430
  2. AC adapter (150 W)
  3. Semi-micro flow cell unit for 5430
  4. HP SM flow cell unit for 5430
  5. Preparative flow cell unit for 5430
  6. Thermo cell for 5430
  7. Thermo cell control unit for 5430

SPECIFICATIONS

5430 Diode Array Detector
Detection type 1,024 bit PDA
Light source D2 lamp, W lamp, Hg lamp for checking wavelength
Wavelength range 190 to 900 nm
Wavelength accuracy ±1 nm
Noise ≤−0,5 × 10−5 AU at 250 nm, 600 nm, under a specified
condition
Drift ≤−0,4 × 10−3 AU/h at 250 nm, 600 nm, under a specified
condition
Response 0,01 sec, 0,02 sec, 0,05 sec, 0,1 sec, 0,5 sec, 1 sec, 2 sec
Slit type 1 nm/4 nm (variable)
Materials of wetted parts Quartz glass, fluororesin, stainless steel
Functions of GLP (a) D2 lamp/W lamp/Hg lamp lighting time, lighting number
of times, and replacement record (b) D2 lamp energy check
(c) W lamp energy check (d) Hg lamp wavelength check
(e) D2 lamp wavelength check
Flow cell 13 μl (optical path length 10 mm)
Thermostat flow cell Optional, environmental temperature range: 15 to 30 °C
Dimensions and weight 340 (W) × 440 (D) × 140 (H) mm, approx. 14 kg
Power supply and Power consumption DC24 V, 3.5 A (maximum) /84 W (power supply from
organizer) Please purchase the AC adaptor (150 W) when
there is no organizer

CHROMASTER DETECTORS AVAILABLE 


  • Model: CM 5430 DAD / CM5430
  • Manufactured by: Merck Hitachi