Cadenza CX-C18 Polar End-Capping ODS Column
Cadenza CX-C18 Polar End-Capping 30mm x 4.6mm, 3μm, 120Å, Analytical HPLC Column, Pressure limits of up to: 20MPa, 250 bar, 3,000 psi
Imtakt Product Number CX001
Column Specifications:
| Base Material: | Silica | 
| Quantity: | 1 piece | 
| Chemistry: | C18 (RP-18, ODS, Octadecyl) | 
| Manufacturer Chemistry Name: | CX-C18 | 
| Endcapping: | Polar End Capping | 
| Matrix: | Silica | 
| Brand: | Imtakt Cadenza | 
| Internal Diameter: | 4.6 mm | 
| Length: | 30 mm | 
| Particle Morphology: | spherical, porous | 
| Particle Size: | 3 μm | 
| Pressure Stability: | up to 250 bar | 
| Pore Size: | 120 Å | 
| Technology: | HPLC | 
| pH: | 2-10 | 
| MW: | up to 10 kDa | 
| USP Class: | L1 | 
High steric selectivity and molecular recognition C18 column for general use, ideal for separation of
isomers and other difficult to separate compounds. Polar end-capping technology provides a more complete coverage of surface silanols and unique selectivity.
Conventional ODS columns, including hybrid-silica type columns, require extensive end-capping in order to decrease residual silanols, which may negatively affect peak shape for basic compounds. Traditionally, this end-capping process has used methyl silane compounds which have a mild hydrophobic interaction. Viewing this interaction in terms of reversed-phase mode, the surface of the stationary phase presents two very different kinds of hydrophobic structures, octadecyl ligands (C18) and the methyl end-capping. These different hydrophobicities may provide an inconsistent response against a solutes interaction with the stationary phase, resulting in poor peak shape and reduced plate counts. Instead of relying on traditional end-capping with trimethyl silane (TMS) compounds, we have succeeded to develop a revolutionary surface modification technology using alcohol structures, which has been adapted to our brand new Cadenza CX-C18. This means that electrostatic interaction from the polar end-capped surface and hydrophobic interaction from the C18 ligand will localize the polarity of the surface and increase the recognition power of a complex compounds hydrophobic/hydrophilic structure. Therefore, Cadenza CX-C18 will have an alternative selectivity for certain compounds and possibly improved peak shape compared to conventional end-capped ODS columns.
- Imtakt's first column featuring modified alcohol polar end-capping
 - Nearly 100% coverage of active surface silanol sites
 - Reduces tailing for basic compounds in acidic conditions
 - Alternative selectivity from traditional C18 columns
 - High steric selectivity and molecular recognition
 - Ideal for difficult isomer or impurity separations
 
Range of Cadenza CX-C18 Columns, Product Numbers:
| Column Length (mm) | Analytical | Semi-prep | |||||
| 1.0 mm I.D. | 1.5 mm I.D. | 2.0 mm I.D. | 3.0 mm I.D. | 4.6 mm I.D. | 6.0 mm I.D. | 10.0 mm I.D. | |
| 3µm Columns, Pressure limits of up to: 20MPa, 250 bar, 3,000 psi | |||||||
| 10 | CX020 | CX030 | CX000 | ||||
| 20 | CX029 | CX039 | CX009 | ||||
| 30 | CX011 | CX071 | CX021 | CX031 | CX001 | CX061 | CX0P1 | 
| 50 | CX012 | CX072 | CX022 | CX032 | CX002 | CX062 | CX0P2 | 
| 75 | CX013 | CX073 | CX023 | CX033 | CX003 | CX063 | CX0P3 | 
| 100 | CX014 | CX074 | CX024 | CX034 | CX004 | CX064 | CX0P4 | 
| 150 | CX015 | CX075 | CX025 | CX035 | CX005 | CX065 | CX0P5 | 
| 250 | CX016 | CX076 | CX026 | CX036 | CX006 | CX066 | CX0P6 | 
| CX007 | |||||||
| 3µm HT Columns, Pressure limits of up to: 50M Pa, 500 bar, 7,500 psi | |||||||
| 10 | CX020T | CX030T | CX000T | ||||
| 20 | CX029T | CX039T | CX009T | ||||
| 30 | CX011T | CX071T | CX021T | CX031T | CX001T | ||
| 50 | CX012T | CX072T | CX022T | CX032T | CX002T | ||
| 75 | CX013T | CX073T | CX023T | CX033T | CX003T | ||
| 100 | CX014T | CX074T | CX024T | CX034T | CX004T | ||
| 150 | CX015T | CX075T | CX025T | CX035T | CX005T | ||
| 250 | CX016T | CX076T | CX026T | CX036T | CX006T | ||
| 3µm UHPLC (UP) Columns, Pressure limits of up to: 10M Pa, 1000 bar, 15,000 psi | |||||||
| 30 | CX021U | ||||||
| 50 | CX022U | ||||||
| 75 | CX023U | ||||||
| 100 | CX024U | ||||||
| 150 | CX025U | ||||||
| 250 | CX026U | ||||||
| 3µm Metal-Free Columns, Pressure limits of up to: 50MPa, 500bar, 7,500psi | |||||||
| 30 | CX021F | ||||||
| 50 | CX022F | ||||||
| 75 | CX023F | ||||||
| 100 | CX024F | ||||||
| 150 | CX025F | ||||||
| 250 | CX026F | ||||||
Column Guard System for Cadenza CX-C18:
| Product Code | Product Name | Product Description | 
| GCCX0C | Guard Cartridge CX-C18 | 3um,Hybrid ODS,end-capped (5x1mm), 3pcs | 
| GCCX0M | Guard Cartridge CX-C18 | 3um,Hybrid ODS,end-capped (10x8mm), 2pcs | 
| GCCX0S | Guard Cartridge CX-C18 | 3um,Hybrid ODS,end-capped (5x2mm), 3pcs | 
| GCH01S | Guard Holder | Guard Holder for 1-6mmI.D. separation columns | 
| GCH02M | Guard Holder | Guard Holder for 10-20mmI.D. separation columns | 
| GCH11S | Guard Holder | Guard Holder for 4.6mm column, enclosed an U-Shape column coupler | 
| GCH12M | Guard Holder | Guard Holder for 10-20mm column, enclosed an U-Shape column coupler | 
All stationary phases can also be made in the following internal diameters, please contact our Sales Team with your specificatons: Nano: 0.02mm, 0075mm | Capillary: 0.1mm, 0.3mm, 0.5mm | Semi-Prep: 20mm, 28mm
This column is also available in particle size 5µm!
- Model: CX001
 - Manufactured by: Imtakt
 

					
											