Item Name |
Product Image |
Price |
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
Overview: Sample preparation is arguably the most critical step within the analytical process. Studies have reported that sample preparation can represent up to 60 % of a laboratory technicians timetable and also forms one of the principal sources... |
 |
... more info
|
QuEChERS kit with extraction materials packed in ready-to-use tubes supporting AOAC 2007.01 methodology. Volume: 50 mLQuantity: 50MgSO4: 6 gNa Acetate: 1.5 g |
 |
£161.00
|
QuEChERS kit with extraction materials packed in ready-to-use tubes supporting Original methodology. Volume: 50 mLQuantity: 50MgSO4: 4 gNaCL: 1 g |
 |
... more info
|
QuEChERS kit with clean-up materials packed in ready-to-use tubes. Volume: 15 mLQuantity: 50MgSO41: 900 mgPSA2: 300 mgPGC3: 150 mg1 MgSO4 removes excess water2 PSA removes sugars, fatty acids, organic acids, and anthocyanine pigments3 PGC (carbon)... |
 |
... more info
|
QuEChERS kit with extraction materials packed in ready-to-use tubes supporting EN 15662 methodology. Volume: 50 mLQuantity: 50MgSO4: 4 gNa Citrate: 1 gNa Citrate Sesquihydrate: 0.5 gNaCL: 1 g |
 |
... more info
|
QuEChERS kit with clean-up materials packed in ready-to-use tubes supporting AOAC 2007.01 methodology. Volume: 15 mLQuantity: 50MgSO41: 1200 mgPSA2: 400 mgPGC3: 400 mg1 MgSO4 removes excess water2 PSA removes sugars, fatty acids, organic acids, and... |
 |
... more info
|
QuEChERS kit with clean-up materials packed in ready-to-use tubes supporting EN 15662 methodology. Volume: 15 mLQuantity: 50MgSO41: 900 mgPSA2: 150 mg1 MgSO4 removes excess water2 PSA removes sugars, fatty acids, organic acids, and anthocyanine... |
 |
£642.00
|
QuEChERS kit with clean-up materials packed in ready-to-use tubes supporting EN 15662 methodology. Volume: 15 mLQuantity: 50MgSO41: 900 mgPSA2: 150 mgC183: 150 mg1 MgSO4 removes excess water2 PSA removes sugars, fatty acids, organic acids, and... |
 |
... more info
|
QuEChERS kit with clean-up materials packed in ready-to-use tubes supporting AOAC 2007.01 methodology. Volume: 15 mLQuantity: 50MgSO41: 1200 mgPSA2: 400 mg1 MgSO4 removes excess water2 PSA removes sugars, fatty acids, organic acids, and anthocyanine... |
 |
... more info
|
QuEChERS kit with clean-up materials packed in ready-to-use tubes supporting AOAC 2007.01 methodology. Volume: 2 mLQuantity: 100MgSO41: 150 mgPSA2: 50 mgC183: 50 mg1 MgSO4 removes excess water2 PSA removes sugars, fatty acids, organic acids, and... |
 |
... more info
|
QuEChERS kit with clean-up materials packed in ready-to-use tubes supporting EN 15662 methodology. Volume: 15 mL, Quantity: 50, MgSO41: 900 mg, PSA2: 150 mg, PGC3: 45 mg; 1 MgSO4 removes excess water; 2 PSA removes sugars, fatty acids, organic... |
 |
... more info
|